Commercial Doors
How to maintain a rolling steel door and spot trouble early
· 12 min read · From the B&B Garage Doors office, Traverse City
Rolling steel door maintenance has two parts. Your staff watch the curtain, guides, bottom bar and hood for damage and note how the door runs. A trained door systems technician inspects and maintains the door at least once a year, as DASMA recommends, and handles anything involving the spring inside the barrel, which is under extreme tension at all times.
Rolling door stuck or binding?
Call the office · Mon to Fri · 7:30 am to 4:00 pm · Free estimates
How does a rolling steel door work
A rolling steel door is a curtain of interlocking steel slats that coils around a barrel mounted above the opening. Torsion springs inside the barrel counterbalance the weight of the curtain, so the door can be raised by hand, by chain or crank or by a motor operator. It is also called a coiling door or a roll-up door.
It helps to know the parts by name.
- Curtain: the sheet of interlocking steel slats that closes the opening and coils up when the door is raised.
- Endlocks and windlocks: fittings on the slat ends that keep the curtain aligned in the guides.
- Guides: the steel channels on each side of the opening that the curtain travels in, fastened to the jambs by wall angles.
- Barrel and spring: the pipe the curtain wraps around, with the counterbalance spring inside it.
- Headplate brackets: the plates at each end that carry the barrel. One holds the tension wheel that sets the spring.
- Hood: the sheet metal cover over the coil.
- Bottom bar: the stiff bar at the bottom of the curtain, usually with a seal or a sensing edge along it.
- Operator: a hand chain hoist, a crank or an electric motor, depending on the door.
What maintenance does a rolling steel door need
It needs a regular look from the people who use it and a scheduled visit from a trained technician. DASMA's Technical Data Sheet 270, written for building maintenance supervisors, says a trained door systems technician should perform periodic inspection and maintenance at least annually or per the door manufacturer's recommendations.
Between those visits DASMA gives the building's own staff a role. It says to evaluate the performance of electric doors quarterly and to test the door's sensing devices frequently. It adds that an event such as high wind or flooding should prompt an immediate evaluation of every door in the facility.
Once a year is the minimum, and doors that run all day benefit from more frequent checks. Our commercial overhead door maintenance checklist covers how to set intervals across a whole building.
| Task | Building staff | Trained technician |
|---|---|---|
| Keep the opening and the sill clear | Every day | Checks at each visit |
| Look over the curtain, guides, bottom bar and hood | On a regular schedule | Inspects up close at each visit |
| Evaluate how an electric door is running | Quarterly | At each visit |
| Test the sensing edge or photo eyes | Frequently and per the operator manual | Tests and repairs |
| Clean and lubricate gears and roller chain | No | Yes |
| Adjust spring tension or replace a spring | Never | Yes |
| Repair or replace slats, endlocks, guides and brackets | No | Yes |
What can your staff safely check on a rolling door
Your staff can check anything that can be seen from the floor or heard while the door runs. DASMA's Technical Data Sheet 269 lays out an evaluation meant for a facility manager or building superintendent.
- 1Clear the doorwayMove anything stored in the path of the door and clear snow and ice off the sill.
- 2Look at the hoodCheck for dents that could make the hood bind against the curtain, and confirm the hood is secure.
- 3Look at the guidesThe gap in each guide should be uniform from top to bottom. Look for bent guide angles and for missing or loose fasteners where the guides meet the wall.
- 4Look at the curtain and bottom barNeither should be bent. Look for endlocks that are loose or missing, and check that the sensing edge is still fastened along the bottom bar.
- 5Run the door and watchThe curtain and bottom bar should move freely in the guides and should not rub the wall above the opening. The bottom bar should stop at the floor when closed and near the stops at the top of the guides when open.
- 6Listen to the operatorAn electric operator that sounds like it is laboring is a warning sign, and the operator itself should not sway as the door moves.
- 7Glance at the tension wheelDASMA says the tension wheel and tension shaft at the end of the barrel should remain stationary while the door runs. If you see movement there, stop and call. Do not touch it.
- 8Write it down and report itNote the door, the date and what you saw. If the door appears to be operating improperly, DASMA says the repair must be made by a trained door systems technician.
What goes wrong with a rolling steel door
Most rolling door trouble comes from impact, wear in the guides, lost spring tension or a tired operator.
- Bent slats: forklifts, trucks and backing trailers dent the curtain. A door run with bent slats can jam in the coil or tear itself apart. Damaged slats can often be replaced without replacing the whole curtain.
- Worn guides and endlocks: guides get knocked out of line, anchor bolts work loose and the curtain starts to rub, jump or bind.
- Lost spring tension: the door gets hard to lift, drifts down on its own or strains its operator. A spring can also break inside the barrel where nobody can see it.
- Operator and chain hoist wear: chain hoists wear, cranks slip and motor operators need their limits and safety devices checked.
- Bottom bar and seal damage: a bent bottom bar will not seat on the floor, and a torn or flattened seal lets in snow, cold air and critters.
What do common rolling door symptoms mean
Each symptom points to a short list of likely causes, and almost none of them are fixed from the floor. Use the chart to describe the problem when you call.
| What you notice | Likely cause | What to do |
|---|---|---|
| Door is hard to lift by chain or crank | Lost spring tension or a dragging curtain | Stop forcing it and call |
| Door drifts down or will not stay open | Counterbalance out of adjustment | Keep the opening clear and call |
| Curtain rubs, jumps or binds in the guides | Bent guide or bent slats or worn endlocks | Stop running it and call |
| Grinding from the coil | Damaged slats or worn barrel bearings | Stop running it and call |
| Skipping or popping while the door moves | Sprockets out of line or a loose roller chain | Call for service |
| Operator runs but the door does not move | A drive key or set screw has let go | Call for service |
| Curtain rolls up crooked or to one side | Barrel out of level or slats off center | Stop running it and call |
| Daylight or snow under the bottom bar | Worn seal or bent bottom bar or ice on the sill | Clear the sill and call if it remains |
| Door closes only while the button is held | Sensing edge or photo eye fault | Call for service |
Why is rolling door spring tension a technician only job
Because the spring inside the barrel is loaded all the time and releasing it the wrong way can kill someone. DASMA warns that the counterbalance assembly and its related parts are under extreme spring tension at all times and that severe personal injury or death may result from improperly attempting adjustments or repairs.
DASMA's first instruction to maintenance supervisors is direct: do not try to adjust the tension wheel, and call for service if the spring needs adjusting. The installation manual from Asta America, one of the door makers we install, says the same and adds that a door that jams or has a broken spring should not be operated.
A rolling door also does not balance the way a sectional door does. DASMA Technical Data Sheet 272 explains that as the curtain rolls up the coil gets larger with every turn, so the load changes along a curve while the spring's pull changes in a straight line. The result is that a rolling door is typically out of balance during some portion of its travel, and DASMA says that should be regarded as part of the normal design.
So a door that feels heavier through the middle is not necessarily a door that needs more tension. Telling the difference is part of the rolling steel certification Tony and Jake both carry. DASMA does give supervisors one number to watch: the force to open the door should not exceed 35 pounds on a hand chain or 25 pounds on a crank, and a significant departure from that may indicate a counterbalance problem requiring a technician.
How do you maintain the operator and chain hoist
Mostly by watching how the door runs and testing its safety devices, then leaving the mechanical work to the technician.
On a motor operated door, test the sensing devices frequently. DASMA says to check a sensing edge at both ends. When the door closes on an obstruction the sensing edge should make it stop, or stop and reverse.
DASMA also points to a rule in the UL 325 safety standard. If a door has no sensing edge or photo eyes, or the sensing devices are not working properly, the close button has to be held with constant pressure for the whole trip down.
At a service visit the technician works through the drive. Gears are checked for broken teeth and debris, then cleaned and lubricated. Sprockets are aligned and the roller chain is inspected, cleaned and lubricated. Limits are set so the bottom bar is not driven tight against the stops and the curtain does not sag when closed.
Do counter shutters need maintenance too
Yes. A counter shutter is a small rolling door, and DASMA's evaluation sheet lists counter doors alongside service doors, fire doors and rolling grilles as products it covers. They close off service windows, concession stands, pharmacy counters and school kitchen lines.
The same staff checks apply at a smaller scale: guides straight and fastened, slats and bottom bar not bent, the curtain moving freely and the lock working. We repair sticking shutters, replace damaged slats and locks and install new manual or motorized ones.
How are fire-rated rolling doors different
A fire-rated rolling door looks much like a service door but has one extra job: it has to close on its own in a fire. NFPA 80 calls for rolling steel fire doors to be inspected and drop tested at least once a year by a trained technician, with written records kept, and that applies to fire-rated counter shutters too.
A fire door is also tested and labeled as a complete assembly, so staff should never pull the release or try to reset a door that has dropped.
We have written that subject up separately. Our guide to fire door inspection requirements covers who is qualified, what a drop test involves and which records to keep, and our fire doors page describes the inspection and repair work.
Who maintains rolling steel doors around Traverse City
B&B Garage Doors and More repairs, services and installs rolling steel doors, roll-up doors and counter shutters across Traverse City and Northern Michigan. Our office is on Blue Star Drive south of town, off US-31.
Weather here works on a rolling door in two ways. The first is the sill. Traverse City often sees more than 100 inches of lake-effect snow in a season, and snow and ice left at the bottom of the opening keep the bottom bar from seating. Keep the sill cleared, and never force a door that is frozen to the floor.
The second is wind. In Acme, at the junction of US-31 and M-72, buildings along the East Arm take wind straight off the bay. Up US-31 in Elk Rapids, the largest village in Antrim County, there is the bay on one side and Elk Lake on the other. And Frankfort, the harbor town on Betsie Bay in Benzie County, faces Lake Michigan weather head on.
DASMA's Technical Data Sheet 291 says a rolling door should be closed before a high wind event, since its wind rating is only valid when it is fully closed, and that DASMA does not recommend operating rolling doors during one.
Sources
- 1.Technical Data Sheet #270: Recommended Rolling Door Maintenance Practices for Building Maintenance Supervisors · Door & Access Systems Manufacturers Association (DASMA)
- 2.Technical Data Sheet #269: Rolling Door Performance Evaluation by a Facility Manager or a Building Superintendent · DASMA
- 3.Technical Data Sheet #272: Rolling Door Counterbalancing · DASMA
- 4.Technical Data Sheet #291: Rolling Doors and High Wind Events · DASMA
- 5.Technical Data Sheet #298: Water Infiltration Under the Bottom Bar of a Rolling Steel Door · DASMA
- 6.400/600 Series Rolling Steel Door Base Installation Manual · Asta America by Janus International
Free estimate
Have our crew take a look
One short form and our office calls you back during business hours. Most repairs are finished on the first visit, and every truck rolls out stocked.
Or call the office(231) 360-5442Mon to Fri · 7:30 am to 4:00 pm · Closed weekends
Request service
About a minute. Our office calls you back.